<LOGO>
FM Transmitter Measurement Report
Created: 2026-01-22 03-07-23
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 43 dBuV YLEX
Pilot RDS Phase Difference
7.6 kHz 2.9 kHz 57 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 63 kHz 19134 0,8571
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,0 dBr 3,62 dBr 5,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" YLEX " 6202 10 (Pop M) 0 1 1 1 3:07, 22.01.2026
RT
-
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6203, 6207, 6205, 6201
FM Scope Max at: 63 kHz MIN: 13 kHz % above 76 kHz: 0,8571 Acquired: 2026/01/22 3.06.18 Total samples: 19134 Equivalent time: 0:15:56 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 5,2 dBr MIN: 1,0 dBr AVE: 3,62 dBr % above 12,2 dBr: 0,0 Last value: 1,0 dBr (2026/01/22 3.06.17) 02.52 02.54 02.56 02.58 03.00 03.02 03.04 03.06 0 2 4 6 Pm [dBr]